K2 Storage System Instruction Manual
September 6, 2006
Chapter 2 Installing the Level 1 Storage System
5. If you do not need trunks, such as on a one-switch system, skip to the next step in
this procedure. If you need trunks, such as on a two-switch system with ISLs, do
the following:
a. Select (Ctrl + Click) the trunked ports. Typically the trunked ports are at the
bottom of the list. In the configuration for 10 Gig ISLs, ports 25 and 26 are Trk1.
b. Click
Modify Selected Ports
.
c. For the trunked ports, set Port Enabled to
Yes
. The 10 Gig ISL ports are disabled
by default, so make sure you enable them. Leave Mode as default of
Auto
, and
set Flow Control to
Disable
.
d. Click
Apply Settings
.
6. On the Port Configuration page, do one of the following: