Transaction Commands
05/29/03
9-15
INV SYS ID 
 
Invalid system identification on card used to access system; no access permitted.
(Unauthorized access may have been attempted.)
 
LIMIT CUTOFF 
 
Limitation was reached, pump was turned off.
 
LOCKED OUT 
 
Card invalidated; no access permitted.
 
NO ALLOC 
 
Allocation option only. A user with no allocation attempted to obtain fuel. No access was 
permitted. 
 
PIN ERROR 
 
Incorrect PIN entered; no access permitted.
 
PMP SW ERROR 
 
Pump switch timer option only. The pump handle was turned on before the timeout period 
was completed. 
 
PUMP DISABLED 
 
User selected a pump that is disabled.
 
PUMP IN USE 
 
User selected a pump already in use.
 
PWR FAIL 
 
The system lost power and was restarted.
 
READ ERROR 
 
Card was improperly coded, damaged or improperly inserted into the card reader. (Could 
also indicate card reader malfunction.) 
 
REORDER FUEL 
 
The tank totalizer dropped below the reorder point; fuel should be ordered. This message 
replaces the original transaction message in all succeeding transactions that pump fuel from 
this tank. The message disappears when the tank inventory exceeds the reorder point (i.e., a 
delivery is made). 
 
TERM ACTIVATE 
 
A pump was activated through the terminal (using the AP command).
 
TIMED OUT 
 
The pump was not accessed (or turned off) within the timeout period.
 
TTY CMD 
 
Pump was inactivated from the data terminal (using the IP command).
 
WRG CARD ENTER 
 
Mag card. In a two-card system, a single card was entered as the second card of a dual card 
entry. 
 
 