Gasboy 1000 Series FMS Operation Manual User Manual
Page 42

GASBOY Series 1000
5-10
05/29/03
PD - PRINT DATE AND TIME
Use the PD command to print the current date and time. In addition, these values also print: the
first transaction to print (TRAN PTR), the last completed transaction (LAST TRAN), the site
shutdown time (SITE DOWN TIME), the site restart time (SITE UP TIME). The shutdown
parameters print only if the AUTO SITE SHUTDOWN parameter was enabled during the SC
command.
If you run the RP command to set the transaction pointer to the last transaction plus 1, and then
run the PD command before a new transaction is generated, the data in TRANS PTR will not
reflect the new number entered during the RP command. TRANS PTR will correct itself as soon
as a new transaction is generated.