System Maintenance Commands

05/29/03

5-5

8.

Repeat this procedure from Step 6 until all your pumps pulse rates are defined. The system
displays: NO. OF TANKS: <1-8>


9.

Type the number of tanks in your configuration and press RETURN. The system displays:
SYSTEM ID:


10. Type the unique number for your system and press RETURN. The system displays:

PRICE DATA FORMAT

0 = NO PRICE DATA

1 = UNIT PRICE

2 = UNIT & TOTAL PRICE

ENTER FORMAT: <0,1,2>


11. Type a number from 0 to 2 and press RETURN to set a price data format for your pumps and

transactions. The system displays:


AUTO PUMP DISABLE

NO. OF ZERO QTY. TRANS. <1-99>


12. Type the number of consecutive zero quantity transactions to trigger automatic pump disable

and press RETURN. Usual values are 3 or 5. The system displays:


LINES PER PAGE: <0-62>


13. Type the number of lines to print on each page. If you are using a terminal/printer

combination, type 62, otherwise, type zero.


The system displays:


CARD EXPIRATION DATE

ENABLE OR DISABLE


14. To disable the card expiration date feature, type D and press RETURN. The system accepts

all dated cards as valid regardless of their expiration date.


To enable the card expiration date feature, type E and press RETURN. The system checks
expiration dates and denies access to those cards with past dates.


The system displays:


AUTO PIN LOCKOUT

ENABLE OR DISABLE


15. To enable automatic PIN lockout (card locked out after three unsuccessful PIN entries), type

E and press RETURN.


To disable automatic PIN lockout, type D and press RETURN.


The system displays:


AUTO SITE SHUT DOWN

ENABLE OR DISABLE