beautypg.com

Gasboy 1000 Series FMS Operation Manual User Manual

Page 102

background image

GASBOY Series 1000

11-2

05/29/03

5. Type

PP to print the pump totals since your last polling session. The

*

prompt reappears.


6. Type

TI to print your tank inventories. The

*

prompt reappears.


7.

If you are using totalizers for periodic totals rather than matching the totalizers on the pump,
type ZP command to reset the pump totalizers to zero. The system displays: RESET PUMP
TOTALIZERS?


8. Type

Y and press RETURN to zero the pump totalizers. The

*

prompt reappears.


9. Type

RP to "free" memory space for more transactions. (See the RP command for more

details.) The system displays: ENTER NO.:


10. Locate the last transaction number from your PD printout (Step 3) and add 1. For example, if

the LAST TRAN entry contained 1227, you would add one to that and get 1228.



Polling Using a PC or Computer

When polling using a PC package or computer, follow the guidelines of the package you’re using
to establish communications and initiate polling with the Series 1000 system. Refer to the PH and
PC commands described earlier in this manual for transmission format and acknowledgement. In
addition to polling, you may also wish to run these commands:

PP to obtain pump totals

TI to obtain tank inventory totals

ZP to reset the the pump totalizers to zero


You will also need to reset the pointer in memory for future polling. To do this, determine the last
transaction received, add one to that value and use the RP command to set this new value as the
next transaction number.