GASBOY Series 1000

5-4

05/29/03

SC - LOAD OR CHANGE SYSTEM CONFIGURATION


Use the SC command to enter or change your system configuration data.

1. At

the

*

prompt, type SC. The system displays ARE YOU SURE?


2.

To cancel and return to the

*

prompt, type N and press RETURN.


To continue, type Y and press RETURN. The system displays SITE NO.:


NOTE: Only

Y or N are valid responses; if you type anything else, the system re-prompts

you until you enter a Y or N.


3. Type your site number and press RETURN. The system displays IDLE MESSAGE: <20

CHARS>.


4.

Type an idle message of up to 20 characters and press RETURN. The system displays: NO.
OF PUMPS: <1-8>


NOTE:

If you try to change the number of pumps while a pump is active, the message
TRAN IN PROGRESS! appears. Wait until the transaction is complete before
changing pump assignments.


5.

Type the number of pumps in your configuration and press RETURN. The system displays:


PUMP

#1

$ OR QTY PULSES? <$ OR Q>


NOTE:

Your system displays the pulse configuration parameters only if the pulse rate
change switch on the Series 1000 MPU board is enabled for changing of pulse
rates. If you do not receive pulse indicator and rate indicators (Steps 5 through
8), the next prompt that appears is NO. OF TANKS. Skip to Step 9.


6.

Type a dollar sign $ if you have a penny pulsing pump and skip to Step 8. Type a Q, for
quantity pulses. The system displays:


PULSES PER GAL. <1000,500,250,100,10,1>.


7.

Type the number of pulses for your pump and press RETURN. The system displays the next
pump number.


NOTE:

If you try to change the pulse rate for a pump while that pump is active, the
message TRAN IN PROGRESS! appears. Change assignments for another
pump or wait until the transaction is complete before changing pulse assignments.