System Maintenance Commands

05/29/03

5-11

SD - LOAD SITE DOWN TIME


Use the SD command to set a daily time when the site is automatically shut down and users
cannot access the fuel dispensing equipment. A **SITE IS DOWN** message appears on the
LCD display. You can still access other software features and can activate a pump for one
transaction through the AP command. Type the time entries using 24-hour military time.

1. At

the

*

prompt, type SD. The system displays:


SITE SHUT DOWN START TIME:

HOURS:

2.

Type the hour (0-23) for the start shutdown time and press RETURN. The system displays:
MINS:


3.

Type the minutes (0-59) and press RETURN. The system displays:


SITE SHUT DOWN END TIME:

HOURS:

4.

Type the hour (0-23) for the end shutdown time and press RETURN. The system displays:
MINS:


5.

Type the minutes (0-59) and press RETURN. The

*

prompt reappears.


If you type the SD command when the auto site shutdown feature is disabled, this message
appears: AUTO SITE SHUT DOWN OPTION MUST BE ENABLED! Use the SC command to
enable this feature.