beautypg.com

Comtech EF Data CDM-570A User Manual

Page 498

background image

CDM-570L/570AL Satellite Modem with Optional Packet Processor

MN-CDM570A

Appendix D

Revision 2

D–40

You must set the working mode for each modem as follows:

Hub CDM-IP Modem – Router-Hub

Hub CDD-564/L IP Quad Demodulator – Router

Remote CDM-570A/570AL-IP Modem – Router-Remote

The Route Table entries are as follows:

Hub CDM-IP Modem – One Route entry for each IP subnet at each remote site

Hub CDD-564/L Demodulator – An Ethernet default route with a Next Hop being the IP of

the Hub CDM-570A/570AL

Remote CDM-570A/570AL-IP Modem – A Satellite default route.

D.3.1.1.3.3 Router Mode (Brouter Enabled) – Point-to-MultiPoint with VLAN

Matching Filters

1)

COMPATIBILITY NOTE – Brouter Point-to-MultiPoint Mode with VLAN

Matching Filters applies only to CDM-IPs and CDD-564/Ls. The entire network

must be configured to operate in the same mode – either entirely configured

to use VLAN Matching Filters, or entirely configured with Filtering Disabled.

2)

As the CDM-570A/570AL-IP can process six times (6X) the number of packets

more than the CDM-570/L, you may not need to use Brouter Mode.

In previous network configurations, ALL remote CDM-IP modems were required to process all

VLAN packets, and then decide whether to forward or discard. In some user applications, this

could result in very high processor utilization numbers and possibly result in ‘overdriving’ the

processor.

The Brouter (Bridged + Router Traffic) Working Mode with VLAN Filtering is a special mode of

operation where VLAN traffic is bridged and non-VLAN traffic is routed using static route table

information. This allows the user to optimally configure the networks to ensure that the remote

modem’s Packet Processor is not ‘overdriven’.