Comtech EF Data CDM-570A User Manual
Page 283

CDM-570A/570AL Satellite Modem with Optional Packet Processor
MN-CDM570A
Serial-based Remote Product Management
Revision 2
8–43
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
Response to
Command
Query
(Instruction Code
and Qualifier)
Response to
Query
Software
Information
(continued)
FW-0020687-,1.1.22,11/08/13
FW-0020688-,1.1.5 ,11/05/13
FW-0000516-,1.1.1 ,19/01/11
Software Revision N/A
34-37 bytes
Query only.
Returns the value of the internal software revision installed in the unit, in the form:
Boot:x.y.z Bulk1:x.y.z Bulk2:x.y.z or
Boot:x.y.zz Bulk1:x.y.zz Bulk2:x.y.zz
N/A
SWR?
SWR=Boot:x.y.zz
Bulk1:x.y.zz
Bulk2:x.y.zz
(see description
of arguments)
Serial Number
N/A
9 bytes
Query only.
Returns the unit’s 9-digit serial number.
Example: <0/SNO?
>0/SNO=176500143
N/A
SNO?
SNO=xxxxxxxxx
(see Description of
Arguments)
Fractional CnC 90-
day Counter
N/A
7 bytes
Query Only.
Returns the number of seconds that Fractional CnC license has been used in 1
year period since the last time the CnC counter was reset to 0.
Example: <0/FCC?
>0/FCC=0000455 (indicating 455 seconds)
N/A
FCC?
=xxxxxxx
(see Description of
Arguments)
Modem Operational
Full Year Counter
N/A
8 bytes
Query Only.
Returns the number of seconds that the unit has been powered on since last reset
of the counter. The counter resets to 0 when it reaches 31536000 seconds
(seconds in 365 days).
Example: <0/SFCF?
>0/FCF=00001342 (indicating 1342 seconds)
N/A
FCF?
=xxxxxxxx
(see Description of
Arguments)