8.3.8

BUC (L-Band Block Up Converter) Commands and Queries (CDM/R-570AL ONLY)

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments for

Command or

Response to

Query

Description of Arguments

Response to

Command

Query

(Instruction Code

and Qualifier)

Response to

Query

Attach

summary BUC

fault to Tx FLT

status

ABA=

1 byte, 0 or 1

Command or Query.

Sets or returns BUC fault-to-Tx fault disposition in the form x, where:

0 = Tx FLT status unaffected by BUC fault

1 = Attach a summary BUC fault to Tx FLT status

ABA=

ABA?

ABA*

ABA#

ABA?

ABA=x

(see Description of

Arguments)

BUC Address

BAD=

2 bytes,

value of 01 to 15

Command or Query.

Sets or returns the BUC Address, in the form xx, where:

xx = address from 01 to 15.

Example: <0/BAD=03

BAD =

BAD?

BAD *

BAD #

BAD?

BAD=xx

(see Description of

Arguments)

BUC Comms

enable

BCE=

1 byte,

value of 0 or 1

Command or Query.

Sets or returns communications, via the FSK link, with an externally connected

Block Up Converter (BUC) in the form x, where:

0 = Disabled

1 = Enabled

Example: <0/BCE=0 (Disabled)

BCE=

BCE?

BCE*

BCE#

BCE?

BCE=x

(see Description of

Arguments)

BUC High Current

Limit

BCH=

4 bytes

Command or Query.

Sets or returns BUC High Current Limit, in mA, the form xxxx, where:

xxxx = value from 500 to 4000

Example: <0/BCH=3100

BCH=

BCH?

BCH*

BCH#

BCH?

BCH=xxxx

(see Description of

Arguments)

BUC Low Current

Limit

BCL=

4 bytes

Command or Query.

Sets or returns BUC Low Current Limit, in mA, the form xxxx, where:

xxxx = value from 0 to 3000

Example: <0/BCL=0600

BCL=

BCL?

BCL*

BCL#

BCL?

BCL=xxxx

(see Description of

Arguments)

BUC Current

N/A

4 bytes

Query only.

Returns BUC Current, in mA, in the form xxxx, where:

xxxx = value from 0 to 9999

When unavailable, response is 0000.

Example: <0/BDC=3100

N/A

BDC?

BDC=xxxx

(see Description of

Arguments)

BUC Voltage

N/A

4 bytes

Query only.

Returns BUC Voltage, in the form xx.x, where:

xx.x = value from 0 to 64.0

When unavailable, response is 00.0.

Example: <0/BDV=43.6 (BUC DC voltage is 43.6 volts)

N/A

BDV?

BDV=xx.x

(see Description of

Arguments)