Comtech EF Data CDM-570A User Manual
Page 346

CDM-570A/570AL Satellite Modem with Optional Packet Processor
MN-CDM570A
Optional Packet Processor - Serial/Telnet CLI Operation
Revision 2
9–50
9.3.8.1.7 Satellite Modem > Configuration > Block Up Converter (BUC)
Configuration
Open the nested Block Up Converter (BUC) Configuration page from the Configuration page.
Figure 9-33. Block Up Converter (BUC) Configuration
Selection
Hot Key Description
BUC Address
A
Set an address for the BUC in the range from 1 to 15.
BUC Communications
M
Toggle to set operation as Enabled or Disabled.
BUC RF Output
R
BUC DC Power
W
BUC 10 MHz Reference
P
BUC Current Alarm Upper
Limit (mA)
H
Set a value in the range from 500 to 4000.
BUC Current Alarm Lower
Limit (mA)
C
Set a value in the range from 0 to 3000.
BUC LO Frequency (MHz)
F
Set a value in the range from 3000 to 65000. Set this value to 0 to
disable.