2 (config: odu) buc: dc-power, 3 (config: odu) buc: 10mhz, 4 (config: odu) buc: alarm – Comtech EF Data CDM-570A User Manual
Page 416

CDM-570A/570AL Satellite Modem with Optional Packet Processor
MN-CDM570A
CDM-570A/570AL ODU (Transceiver, BUC, LNB) Operation
Revision 2
10–42
(CONFIG: ODU) BUC: M&C-FSK ►TX-On/Off
BUC RF Output:
On Off (◄ ►,ENTER)
Use the
◄ ► arrow keys to select the BUC RF Output as On or Off. Press ENTER when done.
10.3.1.1.2.1.2 (CONFIG: ODU) BUC: DC-Power
BUC DC Power:
On Off (◄ ►,ENTER)
Use the
◄ ► arrow keys to select the BUC DC Power as On or Off. Press ENTER when done.
10.3.1.1.2.1.3 (CONFIG: ODU) BUC: 10MHz
BUC 10MHz Reference:
On Off (◄ ►,ENTER)
Use the
◄ ► arrow keys to select the BUC 10 MHz Frequency Reference as On or Off. Press
ENTER when done.
10.3.1.1.2.1.4 (CONFIG: ODU) BUC: Alarm
Set BUC Current Alarm:
Upper Lower (◄ ►,ENTER)
Use this menu to define the upper and lower limits of the BUC current ‘window.’ If the
measured BUC current falls outside this window, an alarm is generated.
Use the
◄ ► arrow keys to select Upper or Lower, and then press ENTER.
(CONFIG: ODU) BUC: Set BUC Current Alarm ► Upper
BUC Current Alarm Upper
Limit:1200mA (◄ ►,▲ ▼,ENT)
To edit the BUC Current Alarm Upper Limit: First, use the
◄ ► arrow keys to select a digit to
edit, and then use the
▲▼arrow keys to change the value of that digit. The valid range of
current is from 500 to 4000 mA. Press ENTER when done.
(CONFIG: ODU) BUC: Set BUC Current Alarm ► Lower
BUC Current Alarm Lower
Limit:1200mA (◄ ►,▲ ▼,ENT)
To edit the BUC Current Alarm Lower Limit: First, use the
◄ ► arrow keys to select a digit to