4 (odu select:) alarms – Comtech EF Data CDM-570A User Manual
Page 390

CDM-570A/570AL Satellite Modem with Optional Packet Processor
MN-CDM570A
CDM-570A/570AL ODU (Transceiver, BUC, LNB) Operation
Revision 2
10–16
(ODU SELECT ► ODU MONITOR:) Tx
TX: SynTune=04.8 Pwr=040
IFLO = 10.7 Temp = 27 oC
This screen shows the Tx Synthesizer and IFLO tuning voltages, the RF Output Power in dBm
and the Transmitter temperature.
(ODU SELECT ► ODU MONITOR:) Rx
RX: Synth Tune = 03.1
IFLO = 10.9 Temp = 28 oC
This screen shows the Rx Synthesizer and IFLO tuning voltages and the Receiver
temperature.
(ODU SELECT ► ODU MONITOR:) Misc
MISC: Ref Tune = 03.0
LNA=000.0mA FAN=568.0mA
This screen shows the Internal Reference Oscillator tuning voltages, the LNA Current in
milliamps and the Fan Current in milliamps.
(ODU SELECT ► ODU MONITOR:) Pwr-Supp1
PS: 24V=23.8 20V=22.6
12V=13.0 10V=10.1
This screen monitors the first four of the six internal power supplies.
(ODU SELECT ► ODU MONITOR:) Pwr-Supp2
PS: +5V=5.5 -5V=-4.9
This screen monitors the remaining two internal power supplies.
10.2.1.2.1.1.1.4 (ODU SELECT:) Alarms
ALARMS: Current Stored
(◄ ►,ENT)
Use the
◄ ► arrow keys to select Current or Stored, and then press ENTER.
(ODU SELECT ► ALARMS:) Current
TX = OK RX = OK
PWR SUP = OK MISC = OK