CDM-570A/570AL Satellite Modem with Optional Packet Processor
MN-CDM570A
Serial-based Remote Product Management
Revision 2
8–45
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
Response to
Command
Query
(Instruction Code
and Qualifier)
Response to
Query
Redundancy
State
N/A
1 bytes, 0 or 1
Query only.
Returns the redundancy state of the unit in the form x, where:
0 = Offline
1 = Online
Example: <0/RED?
>0/RED=1 (selects Online)
N/A
RED?
RED=x
(See Description of
Arguments)
Temperature
N/A
3 bytes
Query only.
Returns the unit internal temperature, in degrees C, in the form sxx, where:
s = sign (+ or –)
xx = value
Example: <0/TMP?
>0/TMP=+26
N/A
TMP?
TMP=sxx
(see Description of
Arguments)
Offline Unit
Status
N/A
6 bytes
Query only. (1:1 set-up)
Sent to the online modem of a 1:1 pair. Returns the fault status information (FLT?)
of the offline modem in the form abcdef, where:
abcdef = The FLT? response information from the offline unit
Note: This is the only way to interrogate the status of an offline modem at the
distant-end of a link.
N/A
OUS?
OUS=abcdef
(see Description of
Arguments)
Faults and
Status
N/A
6 bytes
Query only.
Returns the current highest-priority fault and status codes for the Unit
(hardware), Tx Traffic, Rx Traffic and ODU in the form abcdef, where:
a = Unit faults:
0 = No faults
1 = Power supply fault, +5 volts
2 = Power supply fault , +12 volts
3 = Power supply fault, –5 volts
4 = Reserved
5 = Power supply fault, –12 volts
6 = Tx synthesizer lock
7 = Rx 1st LO synthesizer lock
8 = Rx 2
nd
LO synthesizer Lock
9 = Ref PLL lock
A = Reserved
B = Reserved
C = Reserved
D = Reserved
E = Packet Processor
F = Reserved
N/A
FLT?
FLT=abcdef
(see Description of