beautypg.com

Installing the sensors – Dr. Livingstone, I Presume WELDWISE 2400 User Manual

Page 95

background image

0434-INS-400 Rev. C

7-1

Red: Current sensor

Green: Voltage sensor

Yellow: Force sensor

Blue: Displacement sensor

Figure 7-1 Color-coding on the Monitor-Sensor cable

Installing the Sensors

The Monitor-Sensor cable included with a WeldWise™ 2400 routes input from four possible external
signal sources (Current, Voltage, Force, and Displacement sensors) to the weld monitor. Each sensor
must be attached to the appropriate cable lead as indicated by the color-coding. It is not necessary to
have a sensor attached to every lead, however a Livingston current toroid must always be used.

Note:

Any sensor lead not in use should have its connector protected to prevent contamination of

internal pins.



The Monitor-Sensor cable attaches to the weld monitor as
shown below:

Figure 7-2 Attaching the Monitor-Sensor
cable to a 2400