This option is the same as the Import Masters
command above, except that the archive
database has been compressed and stored to a
floppy disk previously by an Export Masters
To Floppy
command.

WARNING: Welds cannot be monitored while

the Import Masters From Floppy option is in
use. Any remote user interface windows
must also be closed
. If the Cancel button is
used, the weld monitor must be shut down and
restarted. DO NOT shutdown the weld monitor
during this operation.

Import Setup
This option imports general setup and sensor
calibration data previously stored in an archive
database by an Export Setup command. The
setup archive database file name is setup.mdb.
This command will overwrite the existing setup
and calibration data.

WARNING: Welds cannot be monitored while

the Import Setup option is in use. Any
remote user interface windows must also be
closed
. If the Cancel button is used, the weld
monitor must be shut down and restarted. DO
NOT shutdown the weld monitor during this
operation.

Import Setup From Floppy
This option is the same as the Import Setup command above, except that the archive database has
been compressed and stored to a floppy disk previously by an Export Setup To Floppy command.
Only one setup archive can be stored on a floppy disk.

WARNING: Welds cannot be monitored while the Import Setup From Floppy option is in use.

Any remote user interface windows must also be closed. If the Cancel button is used, the weld
monitor software must be shut down and restarted. DO NOT shutdown the weld monitor during
this operation.

Figure 6-26 Import Setup

Figure 6-27 Import Setup From Floppy