7. TROUBLE WITH BIN SELECTS OR ACCEPT/REJECT
PROBLEM
POSSIBLE CAUSE OR
SYMPTOM
POSSIBLE FIX
No Master has been created for the
requested Binary Select. The value will
default to 0.
If a Master does not already exist for this Bin Select, create a
new Master for this Binary Select value. (Refer to Chapter 5,
WMS Quick Start Guide or Supplementary Procedure, if
applicable).
No master has been updated to the weld
monitor.
In the Mastering screen select the Master and click Update to
load the master for use.
Masters are not enabled. The Binary Select
Value will default to 0.
Go to the General Setup menu and set Masters Enabled to
Yes.
External Binary Select is not working.
Go to the General Setup menu and set Binary Select Mode to
External. Refer to the General Setup Section, Binary Select
Mode in Chapter 6, WMS Quick Start Guide for information on
External select modes.
THE BIN SELECT IS
ALWAYS "0": The weld
summary screen indicates
that weld data is being
recorded with the Binary
Select of 0. Main screen
indicates that the weld was
recorded with No Master.
Weld Monitor Malfunction.
Shutdown and restart the weld monitor. If the problem persists,
contact Livingston Service.
Internal Binary Select is not set correctly.
Go to the General Setup menu and set Binary Select Mode to
Internal. Set Internal Binary Select to the desired value.
External Binary Select is not working.
Go to the General Setup menu and set Binary Select Mode to
External. Refer to the General Setup Section, Binary Select
Mode in Chapter 6, WMS Quick Start Guide for information on
External select modes. Note: A binary select of 16 indicates that
a Master was created when the external input were selecting a
binary select of 0.
THE BIN SELECT IS
INCORRECT AND IS
NOT "0": The weld
summary screen indicates
that weld data is being
recorded with the wrong
Binary Select.
Weld Monitor Malfunction.
Shutdown and restart the weld monitor. If the problem persists,
contact Livingston Service.