Dr. Livingstone, I Presume WELDWISE 2400 User Manual
Page 192

454-APP-299 Rev. B
12-22
unique. For example, if the IP address of your computer was 10.43.5.23, a similar
address would be 10.43.5.67.
− The Subnet Mask should be identical to other local Subnet Masks.
• If your company has an existing network that is controlled by a Server, your systems
administrator or IT person may want to change the IP address of the Livingston weld monitor
to your local IP address.
− The default IP address of the 2400/Pod Server is 192.168.2.xxx, where "xxx" is the last
3 digits of the monitor's serial number.
− If your local IP address does not use these number groupings, you may type a "." to
indicate a space.
− You may want to select the "Obtain IP address from a DHCP server" option from the
TCP/IP Properties window if you are using DHCP.
• If you are using a personal laptop or do not have a company network, you may want to change
the IP address of your computer to the 2400/Pod Server's IP address.
− The default IP address of the 2400/Pod Server is 192.168.2.xxx, where "xxx" is the last
3 digits of the monitor's serial number.
• The 2400/Pod Server's default User Name is Administrator.
The default Password is 2400.
The default Workgroup is Livingston.