0433-INS-400 Rev. E

6-38

Setup Utilities

Input Monitor

This option displays the input monitor
screen, which shows the data values from
external sensors and inputs. A Zero
Displacement
utility is also provided.

Toroid Settings

This utility is used adjust the toroid
calibration. The calibration is set at the
factory for use with a toroid that has a CF of
0.400 (calibration factor of 400). When
installing a toroid, the CF setting labeled on
the toroid should be entered as a whole number in this screen (Example CF of 0.354 should be
entered as 354).

Calibrate Voltage

This utility is used to calibrate the voltage sensor input channel. The voltage calibration values
are set at the factory, and therefore do not require calibration.

Calibrate Force

This utility is used to calibrate the force sensor input channel. The Force channel must be
calibrated when a new force or pressure sensor is installed.

Calibrate Displacement

This utility is used to calibrate the displacement sensor input channel. This channel should be
calibrated when a new displacement sensor is installed.

Figure 6-51 Setup Utilities