Dr. Livingstone, I Presume WELDWISE 2400 User Manual
Page 56
0433-INS-400 Rev. E
6-10
• Energy
The calculated energy during the halfcycle, equal to Current RMS multiplied by Voltage RMS. The
average energy for a segment or weld.
• Power Factor
Power Factor is not yet implemented and will display zero.
• Cyc Len
Cyc Len shows the number of samples per halfcycle in the A-D conversion. For Rtype 0, this
number is typically between 102 and 107 (half cycle @60Hz sampled at 12.5kHz). This field is
used by Livingston technicians as a diagnostic tool and should generally be ignored.
• Date/Time
The date and time when the halfcycle, segment or weld data was recorded.
• MasterID
Name of the master used to qualify the weld.
• Bin Select (Binary Master Select)
For each POD / ID there are up to 15 masters which are selected using the binary select inputs. The
Bin Select reported in the weld data indicates the binary select setting or master number used for
this weld. Example: A Bin Select of 3 indicates that master associated with binary select 3 was
used. Typically the binary select number corresponds with the weld schedule number or the
sequential order of welds made by the welder during a part cycle.
Note: A binary select of 16 may appear if a master was created while an external binary select of 0
was selected. This is intended as a diagnostic aide for those trouble-shooting external binary
select timing problems.