Rockwell Automation 1441-PEN25-Z Enpac 2500 Data Collector User Manual

Page 88

background image

88

Rockwell Automation Publication GMSI10-UM002D-EN-E - August 2012

Chapter 2

Setting Up Measurements

Spectrum Alarms in the Enpac 2500 Data Collector

The Enpac 2500 supports band alarms with up to ten bands.

You can have the data collector collect a spectrum measurement if a
magnitude alarm is in alarm. Set the Collect and store condition in the
Edit Storage Specification dialog to ‘On Magnitude Alarm’ for the storage
specification for the spectrum measurement definition.

You must set Trigger to ‘Yes’ for any alarms you want to appear in the
Enpac 2500 during data collection. If you set Trigger to ‘Yes’ for two or
more alarms for the same measurement definition, Emonitor combines the
alarms before sending the combined alarm to the Enpac 2500.

For more on how Emonitor combines alarms before sending them to the
Enpac 2500,

see Alarms and the Data Collector on page 95

.

The Enpac does not support spectrum alarms. You can still set up the alarms for
the spectrum measurement definitions. Emonitor tests the data against the
alarms after you unload the data.

Typical Spectrum Measurement Definitions

This figure shows the setup for typical spectrum measurement definitions. The
first is a standard spectrum, the second is an order normalized spectrum, and the
third is a time synchronous spectrum.

Figure 17 - Spectrum Measurement Definitions

The following table shows the collection specifications (in the same order as the
measurement definition table above).

The following table shows the transducer specification in the collection
specifications.

Table 25 - Collection Specifications for Spectrum Measurement Definitions

Transducer

Window

Signal Detection

Fmax

Lines

Phase

Order Norm?

Averages

Accelerometer

Hanning

Peak

2 kHz

400

No

No

4 linear

Accelerometer

Hanning

Peak

10 orders

400

No

Yes

4 linear

Accelerometer

Hanning

Peak

2 kHz

400

No

No

4 time synch.

Table 26 - Transducer Specification in Spectrum Collection Specifications

Name

Base Unit

Input Type

Units

Calibration Value

DC Offset

Accelerometer

Acceleration

ICP Accel

g

100

0