Collect a User-defined Measurement

Follow these steps to collect a user-defined measurement.

1.

After setting up the measurement, connect the proper transducer.

2.

Press Enter from the Offroute User screen to start the measurement.

The measurement screen appears. The Enpac 2500 data collector ranges
and collects the data.

3.

If desired, press F3 (Notes) to assign inspection codes to each point.

The Enpac 2500 data collector unloads the inspection codes when you
unload the unscheduled data to Emonitor.

See

Select Inspection Codes on page 126

.

4.

If you want to collect data again for this point, press F2 (Retake) to collect
the measurement again.

Window

Type of window to be applied to the waveform measurement prior to computing
the spectrum

Hanning (default), Hamming, Flat Top, Rectangular

Averages

Sets the number of individual data sets to be incorporated into the average
calculation.

Numeric value
4 (default)

Overlap

The percentage of overlap during the averaging. It can be used to reduce the total
time that it takes to collect the data.

Percentage

Type

Sets the type of averaging for the measurement.

Spectral (default)
Time Synchronous
Peak Hold
Exponential

Ext Trig Slope

The input signal slope to be used for externally triggering the measurement.
+ve - Defines the trigger event to occur on a rising edge.
-ve - Defines the trigger event to occur on a falling edge.

+ve (default)
-ve

Level

The amplitude level for externally triggering the measurement. The level is a
percentage of the trigger full scale range.

Numeric: 0.0 (default)

Bin Zeroing

Enables/disables bin zeroing. When set to Off, the bins below the selected high
pass filter are not zeroed. That is, data still appears but is attenuated by the filter
shape.
Set bin zeroing to On when you want to be sure unwanted frequencies do not
affect data. Set bin zeroing to Off when you want to be aware of the presence of
unwanted frequencies.

On (default)
Off

Table 37 - Offroute User Parameters

Parameter Name

Description

Values/Comments

Window

Description

Hanning

A general purpose window to use on random type data when frequency resolution is more important than amplitude
accuracy. Use this setting for most of your machinery monitoring activities.

Hamming

Another general purpose window with slightly different window characteristics than the Hanning window.

Flat Top

Use this when amplitude accuracy is more important than frequency resolution. In data with closely spaced peaks, a Flat Top
window may smear the peaks together into one wide peak. Use this for sinusoidal or calibration signals.

Rectangular

The Enpac 2500 data collector does not apply a window. Use this only for transient signals that die out before the end of the
time sample, or for exactly periodic signals within the time sample.