Why won’t emonitor load a list to the enpac 2500, Why does emonitor rebuild the quickload files, How do i load a list to the pcmcia card – Rockwell Automation 1441-PEN25-Z Enpac 2500 Data Collector User Manual

Page 307: How do i tell when loading or unloading is done

background image

Rockwell Automation Publication GMSI10-UM002D-EN-E - August 2012

307

Frequently Asked Questions and Answers

Appendix B

Why won’t Emonitor load a list to the Enpac 2500?

First, check the communication between Emonitor and the Enpac 2500. Note
that the baud rate setting in the data collector must match the baud rate setting in
Emonitor.

If the communication link between them is correct, it may be that the list

is

already loaded in the Enpac 2500. You must either delete the list or initialize the
memory before you can reload a list already in the Enpac 2500.

Why does Emonitor rebuild the Quickload files?

Emonitor rebuilds a Quickload file before loading it to the data collector when
any one of the following occur.

The list is not stored with the Use quickload file option selected.

The measurement definitions in the list change.

The inspection codes in the list change.

The locations in the list change.

The hierarchy level of items in the Hierarchy Tree that affect measurement
definitions in the list change.

The collection specification of a measurement definition in the list
changes.

The Override collect on alarm settings (in the Load Option dialog) are
selected.

The list has been saved since last loaded.

How do I load a list to the PCMCIA card?

Emonitor can load lists to either the Enpac internal memory, or to a memory
card. You control the destination for lists with the Route Memory parameter in
the Setup Utility screen in the Enpac 2500.

Set Route Memory to ‘Internal‘ to store lists and data in internal Enpac
memory.

Set Route Memory to ‘Card‘ to store lists and data to the PCMCIA card
in the card slot.

How do I tell when loading or unloading is done?

Emonitor and the Enpac 2500 establish communication as soon as the following
are both true.

TIP

The Route Memory parameter is not applicable when unloading data.
Emonitor can unload lists from both the Enpac internal memory and the
PCMCIA card at the same time.