beautypg.com

Frf frequency response function extension module, Chapter 11, Chapter – Rockwell Automation 1441-PEN25-Z Enpac 2500 Data Collector User Manual

Page 287

background image

Rockwell Automation Publication GMSI10-UM002D-EN-E - August 2012

287

Chapter

11

FRF Frequency Response Function Extension
Module

The Frequency Response Function (FRF) extension module is an optional
module for the Enpac 2500 data collector. You install the extension module with
the FRF Frequency Response PCMCIA memory card.

See

Installing Optional Extension Modules on page 189

for installation

instructions.

The Enpac 2500 data collector FRF extension module lets you determine the
natural frequencies of a machine or structure in a more sophisticated manner
than the Bump Test module. Rather than simply detecting the frequencies where
resonances occur, it captures information about the frequency response of the
structure being tested.

You can use the FRF data in conjunction with a modal analysis software
package to model the way the structure reacts to forces applied to it.

You can use the FRF module to capture information about how a machine
moves when it is running. You can use this information with the Operation
Deflection Shape (ODS) analysis software.

The FRF module includes the following features:

Simple selection of measurement type from a list of predefined options, for
example, mobility, stiffness, and apparent mass.

FRF trace colored green or red to illustrate high or low coherence.

Optional automatic parameter setting for input ranges, number of lines,
and windowing.

Compatibility with ODS analysis software.

Topic

Page

Newtons Law and Apparent Mass

288

Setting Up an FRF Measurement

288

FRF Module Setup

290

Collect FRF Data

294

Field Calibration

297

Saving, Reviewing, and Deleting FRF Measurements

299

IMPORTANT

The FRF extension module is for Offroute/unscheduled measurements only.
The Emonitor software does not import this type of data.

This manual is related to the following products: