Bump Test Application
Chapter 7
Recalling a Setup
You can recall a previously saved setup and use it to record another measurement.
The setup may have been saved only as a setup, or may have been saved with the
recorded data.
Refer to Saving a Bump Test Setup and Measurement on page 200
.
1.
Connect the transducer to the Enpac 2500.
Refer to Connect a Transducer to the Data Collector on page 120
2.
Attach the transducer(s) to the machine case or structure.
3.
Select Bump Test on the Main Menu and press the READ/OK key. The
Bump Test screen appears.
4.
Select Recall and press the READ/OK key.
The Bump Test - Load Setup screen appears.
5.
Highlight the filename that you want to recall and press F4 (Open).
6.
You can edit the settings or start collecting more date.
Refer to Setting Up and Collecting Bump Test Measurements on page 196
.
To highlight a filename, press the UP or
DOWN ARROW key.