Rockwell Automation 1441-PEN25-Z Enpac 2500 Data Collector User Manual
Page 304

304
Rockwell Automation Publication GMSI10-UM002D-EN-E - August 2012
Appendix A
Specifications
Signal Measurement cont.
Input Signal Range
Transducer Check
Signal
Auto Range
Dynamic Range
Accuracy
Frequency Range
Filters - High Pass
Bearing Condition
gSE Filters
ESP Filters
Real Time Rate
FFT Resolution
Time Block Length
Averaging
Alarms
Note Codes
Window Types
Non ICP: ±12 V or 0 to 24 V
ICP: 0 to +20 V
Bias Voltage Integrity
RMS
Peak
Peak to Peak
True Peak
True Peak to Peak
Yes
90 dB typical
5%
Upper (Fmax) all inputs = 40 kHz
Lower (Fmin) DC input = DC
AC/ICP input = 0.16 Hz
H/W integrated input = 0.22 Hz
H/W filters are 2nd order
3 dB points 0.22, 0.44, 2, 5.3, 10, 23.1, 70 Hz
2, 10, 70 filter supported in route mode
gSE
ESP
100, 200, 500, 1000, 2000, 5000 Hz
0.6-1.25; 1.25-2.5; 2.5-5; 5-10; 10-20 kHz
40 kHz (single channel)
100…12,800 lines
256…16,384 samples
Time
Spectral
Exponential
Peak Hold
Overall
Spectrum
100 note codes (select up to 6)
Codes downloaded from Emonitor
Rectangular
Hanning
Hamming
Flat Top
Enpac 2500 Technical Specifications
Product Feature
Specification