Examples
To run the Connectivity Test on a drive at device path 2/0.4.0 on Windows:
hp_ltt -f test p=2/0.4.0 testname="Connectivity Test"
To run the previous test with I/O history enabled:
hp_ltt -f test p=2/0.4.0 testname="Connectivity Test"
iohistory=enable
To run the previous test with a test option that causes the test to be run three
times:
hp_ltt -f test p=2/0.4.0 testname="Connectivity Test"
testopt=”Looping Value:3”
To run the LTO Drive Assessment Test on a drive at path 2/0.4.0 on Windows:
hp_ltt -f test p=2/0.4.0 testname="LTO Drive Assessment
Test" testopt="Allow Overwrite:True"
To run the LTO Drive Assessment Test on a drive at path 2/0.4.0 on Windows,
with I/O history enabled:
hp_ltt -f test p=2/0.4.0 testname="LTO Drive Assessment
Test" testopt="Allow Overwrite:True" iohistory=enabled
To run the DDS Drive Assessment Test on a drive at path 236/0.3.0 on
Windows:
hp_ltt -f test p=2/0.4.0 testname="DDS Drive Assessment
Test" testopt="Allow Overwrite:True"
Running utilities (CLF)
Description
L&TT can be launched from the command line to run various utilities. L&TT runs
the test specified by the name parameter.
The following utilities are currently supported from the command line:
•
“System Config utility” (page 171)
Syntax
hp_ltt -f utility name=
[instname=
Parameters
Enter the name of the utility to run. The names of the supported
utilities are:
•
System Config Utility
For the proper syntax, see the Command line syntax entry for
the desired command in
. This
parameter is required.
name
password
Optional. Specify a password. Passwords in L&TT are used
to unlock certain functionality of the program. See
for more information about passwords.
If the password is invalid, L&TT resets the password to an
empty string.
instname
Specify a name for this instance of L&TT. This parameter is
optional for the first instance of L&TT and required for all other
instances of L&TT. If this parameter is supplied, the log files
from this instance will be created in a logs_
folder in the logs folder of the L&TT installation directory
or directory specified by dirpath.
dirpath
Specify the absolute path for the temporary directory used by
L&TT for its runtime files. This parameter is optional when L&TT
Command line functions