Dlt sram check test (short and long versions), Esl vendor id test, Full sweep test – HP StoreEver TapeAssure Software User Manual
Page 112

DLT SRAM Check test (short and long versions)
CAUTION:
These tests are destructive and will overwrite data on the media that is present in your
product.
Description
These tests check DLT 8000 drive logs for evidence of SRAM chip
corruption, and they perform a read/write test to check the drive for
susceptibility to SRAM corruption problems. The tests are destructive to
data on the cartridge in the drive. These tests are only available for DLT
drives.
NOTE:
For instructions on how to perform this test, see
or
Running the tests (CSI) (page 73)
When to run
Run the short version of the test when you suspect the drive may be
responsible for CRC errors and want to do a quick test to verify. Run
the long version to perform a more extensive analysis.
Average duration
~20 minutes (short version), or up to 1.5 hours (long version)
Other notes
You must have a write-enabled tape in the drive, and the drive must be
ready before starting this test or it will fail. Test will overwrite all data
on the media.
Available for
DLT 8000
ESL Vendor ID test
Description
Toggles the Vendor ID in an ESL library between HP and Compaq.
NOTE:
For instructions on how to perform this test, see
or
Running the tests (CSI) (page 73)
When to run
Run this test to change the vendor ID, which may be required for some
applications to work properly.
Average duration
< 1 minute
Other notes
Test requires firmware version 3.40 or later.
Available for
ESL libraries
Full Sweep test
Description
This test script moves the robotics through the full range of motion to
help prevent reliability issues with the brush tracks. This test is available
for the C7200 and C7145 library models.
NOTE:
For instructions on how to perform this test, see
or
Running the tests (CSI) (page 73)
When to run
Run this test if the results of a Device Analysis test recommend that you
run this test. This recommendation is based on reviewing library log
data for certain critical errors, including those related to issues with the
brush tracks.
Average duration
Up to 2.5 hours, depending on whether the long or short test is selected.
Other notes
Test will not overwrite any data on the media. Data from this test is
logged into the library for future use by support personnel.
Available for
C7145 and C7200 libraries
112