beautypg.com

GW Instek PEL-2000 Series User Manual User Manual

Page 255

background image

APPENDIX

255

Current

Accuracy

±0.4% F.S.

MEASUREMENT

VOLTAGE READBACK
Range

0~16V

0~80V

Resolution

0.5mV

2.5mV

Accuracy

±(0.05%set + 0.05% F.S.)

CURRENT READBACK
Range

0~2A

0~20A

Resolution

0.0625mA

0.625mA

Accuracy

±(0.1%set + 0.1% F.S.)

PROTECTIVE

Over Power Protection
Range

1~102W

Resolution

0.5W

Accuracy

±(2%set + 0.25% F.S.)

Over Current Protection
Range

0.25~20.4A

Resolution

0.05A

Accuracy

±(2%set + 0.25% F.S.)

Over Voltage Protection
Range

1~81.6V

Resolution

0.2V

Accuracy

±(2%set + 0.25% F.S.)

Over

Temperature
Protection

ؒ85Ԩ

Rated Power Protection:
Value

110W

Accuracy

±2%set

GENERAL

SHORT CIRCUIT
Current(CC)

ؒ2.2/2A

ؒ22/20A

Voltage(CV)

0V

0V

Resistance(CR)

ؒ3.75Ω

ؒ0.075Ω

INPUT
RESISTANCE
(LOAD OFF)

800KΩ(Typical)