beautypg.com

Configure channel control interface – GW Instek PEL-2000 Series User Manual User Manual

Page 235

background image

INTERFACE

235

Configure Channel Control interface

Channel control
configuration

Connector

Screwless connector.

Wire Gauge

22-28 AWG (24 AWG
recommended).

Wire connection

10 mm strip gauge for
connection.

Input

0-10V.

Pin Assignment

1 GND

Negative potential of the load
input terminal.

2 I MON (OUTPUT)

Load input current monitor;
where 0V = 0% of input current
and 10V = 100% of input
current.

3 V MON (OUTPUT)

Load input voltage monitor;
where 0V = 0% of input voltage
and 10V = 100% of input
voltage.

4 Ext Voltage ref

(INPUT)

External voltage reference;
Where 0V=0% of rating
voltage/current and 10V =
100% of rating voltage/current.
The external voltage reference
is for CC and CV mode.