beautypg.com

GW Instek PEL-2000 Series User Manual User Manual

Page 141

background image

OPERATION

141

Choose which Memory data will be
used for the sequence. CH1 MXXX ~
CH8 MXXX.

Run: Skip – Auto - Manual

Choose whether to run the sequence in
the program automatically, skip the
sequence or manually start the
sequence.

On-Time: 0.1 ~ 60.0 seconds

Determines how long the sequence will
run for (seconds).

Off-Time: Off – 0.1 ~ 60.0 seconds

Sets how long the sequence will stay off
for (in seconds) between each sequence.
Assuming Short time is not set to OFF,
Off-Time will always run after On-
Time.

Short Time: Off – 0.1 ~ On-Time (seconds)

Determines how long a short circuit will
last (seconds). However the shorting
time cannot be longer than the On-time.
Short Time will start at the same time as
On-time.

P/F Time: Off – 0.1 ~ (On-Time+Off-Time)-0.1
(seconds)