PEL-2000 Series User Manual

192

03/02/09

10 : 30

Configure

Other

System

Info

Load

Interface Time Set

3. Use the Selector knob to move

the cursor down to Go-NoGo
Tone (below the initial screen).

4. Press the Selector knob to

highlight Go-NoGo Tone, then
turn to change to ON/OFF.

5. Press the Selector Knob or Enter

to confirm selection.

Adjusting Slave Knob Settings

Background

Channel loads can be edited using the local load
module or the Mainframe. When using the local
load module selector knob (slave knob) to edit a
load, the load module display can be set to two
different types: SetValue and Measured.

When a load is ON, SetValue will always display
the set value (A Value, B Value) on the local load