INTERFACE

239

Connection

Input: active low (0-1V), active high (4-5V)

Inputs (5V, 10kΩ pull-up resistor)

Open collector outputs (Load status, Alarm
Status, +5V) maximum 30VDC with 1.1V
saturation voltage (100mA).

When enable is on (active low), the following is
disabled from the mainframe: activating loads
and recalling preset or setup memory.

Frame Link
constraints

Maximum 5 (1 master + 4 slave units) devices
can be linked altogether with a maximum cable
length of 30cm for each cable.

All the connected devices must be turned on.

No loop or parallel connections

Configure Go/NoGo Interface

Connection

Use a DSUB (DB-15 Female)
connector to connect to the
Go/NoGo port.

The Go/NoGo port is an
output only port.

Pin assignment

Pin1

Ch1_GO/NG

Pin9

Ch5_GO/NG

Pin2

GND

Pin10

GND

Pin3

Ch2_GO/NG

Pin11

Ch6_GO/NG

Pin4

GND

Pin12

GND