AFG-2225 Series User Manual

98

Range

Phase deviation/shift

0~360°

Defualt phase

180°

Select the PM Source

The function generator excepts internal or external sources for phase
modulation. The default source is internal.

Panel Operation

1. Press the MOD key.



2. Press F4 (PM).





3. Press F1 (Source).

our



4. Press F1 (INT) or F2 (EXT) to

select the source.





~





5. Press return to return to the

previous menu.

Return

External Source

Use the MOD INPUT terminal
on the rear panel when using an
external source.

IN

OUT

Trigger

Counter

Trigger

MOD

Note

If the modulation source is set to external, the
phase deviation is controlled by the ±5V MOD
INPUT terminal on the rear panel. For example, if
the modulation voltage is +5V, then the phase
deviation is equal to the phase deviation setting. If
the modulation voltage is less than +5V, then the
phase deviation will be less than the phase
deviation setting.