beautypg.com

Source[1|2]:sum:state, Source[1|2]:sum:source – GW Instek AFG-2225 User Manual User Manual

Page 237

background image

REMOTE INTERFACE

237

SOURce[1|2]:SUM:STATe

Source Specific
Command

Description

Turns SUM Modulation on or off. By default SUM
modulation is off.

Note

Burst or sweep mode will be disabled if SUM
modulation is enabled. As only one modulation is
allowed at any one time, other modulation modes
will be disabled when SUM modulation is
enabled.

Syntax

SOURce[1|2]:SUM:STATe {OFF|ON}

Example

SOUR1:SUM:STAT ON

Enables SUM modulation

Query Syntax

SOURce[1|2]:SUM:STATe?

Return Parameter 0

Disabled (OFF)

1

Enabled (ON)

Example

SOUR1:SUM:STAT?
ON

SUM modulation is currently enabled.

SOURce[1|2]:SUM:SOURce

Source Specific
Command

Description

Sets or queries the SUM source as internal or
external. Internal is the default source.

Note

If an external SUM source is selected, the
amplitude is controlled by the MOD INPUT
terminal on the rear panel.

Syntax

SOURce[1|2]:SUM:SOURce {INTernal|EXTernal}

Example

SOUR1:SUM:SOUR EXT

Sets the SUM source to external.

Query Syntax

SOURce[1|2]:SUM:SOURce?

Return Parameter INT

Internal