beautypg.com

Source[1|2]:square:dcycle – GW Instek AFG-2225 User Manual User Manual

Page 211

background image

REMOTE INTERFACE

211

Syntax

SOURce[1|2]:DCOffset {< offset>
|MINimum|MAXimum}

Example

SOUR1:DCO MAX

Sets the offset to the maximum for the current
mode.

Query Syntax

SOURce[1|2]:DCOffset? {MINimum|MAXimum}

Return Parameter

Returns the offset for the
current mode.

Example

SOUR1:DCO?

+3.0000E+00

The offset for the current mode is set to +3 volts.

SOURce[1|2]:SQUare:DCYCle

Source Specific
Command

Description

Sets or queries the duty cycle for square waves
only. The setting is remembered if the function
mode is changed. The default duty cycle is 50%.

Note

The duty cycle of square waveforms depend on the
frequency settings.
1.0% to 99.0%(frequency≤100 KHz)
10% to 90% (100 KHz ≤ frequency ≤1MHz)
50% (frequency ≤ 25 MHz)

If the frequency is changed and the set duty cycle
cannot support the new frequency, the highest
duty cycle available at that frequency will be used.
A “settings conflict” error will result from the
above scenario.

For square waveforms, the Apply command and
AM/FM modulation modes ignore the duty cycle
settings.

Syntax

SOURce[1|2]:SQUare:DCYCle {< percent>
|MINimum|MAXimum}