267

COUNter:VALue?

Instrument
Command

Description

Returns the current value from the frequency
counter.

Syntax

COUNter:VALue?

Example

COUNter:VALue?

+5.00E+02

Returns the frequency as 500Hz.

PHASE

The phase command remotely controls the phase and channel
synchronization.

SOURce[1|2]:PHASe

Instrument
Command

Description

Sets the phase.

Syntax

SOURce[1|2]:PHASe {||}

Parameter

phase

-180~180

min

Sets the phase to the minimum
value.

max

Sets the phase to the maxium
value.

Example

SOURce1:PHASe 25

Sets the phase of channel 1 to 25°.

Query Syntax

SOURce[1|2]:PHASe? {MAX|MIN}

Return Parameter phase

Returns the current phase.

Example

SOURce1:PHASe?

26