-158 String data not allowed

An unexpected character string was used where
none were expected. Example: A character string is
used instead of a valid parameter.
SOURce1:SWEep:SPACing ’TEN’

-161 Invalid block data

Invalid block data was received. Example: The
number of bytes sent with the DATA:DAC
command doesn’t correlate to the number of bytes
specified in the block header.

-168 Block data not allowed

Block data was received where block data is not
allowed. Example:
SOURce1:BURSt: NCYCles #10

-170~178 expression errors

Example: The mathematical expression used was not
valid.

Execution Errors

-211 Trigger ignored

A trigger was received but ignored. Example:
Triggers will be ignored until the function that can
use a trigger is enabled (burst, sweep, etc.).

-223 Too much data

Data was received that contained too much data.
Example: An arbitrary waveform with over 4096
points cannot be used.

-221 Settings conflict; turned off infinite burst to allow immediate trigger
source

Example: Infinite burst is disabled when an
immediate trigger source is selected. Burst count set