beautypg.com

Source[1|2]:burst:internal:period – GW Instek AFG-2225 User Manual User Manual

Page 253

background image

REMOTE INTERFACE

253

Example

SOUR1:BURS:NCYC?
+1.0000E+02

The burst cycles are set to 100.

SOURce[1|2]:BURSt:INTernal:PERiod

Source Specific
Command

Description

Sets or queries the burst period. Burst period
settings are only applicable when the trigger is set
to immediate. The default burst period is 10 ms.
During manual triggering, external triggering or
Gate burst mode, the burst period settings are
ignored.

Note

The burst period must be long enough to output
the designated number of cycles for a selected
frequency.
Burst period > burst count/(waveform frequency
+ 200 ns)
If the period is too short, it is automatically
increased so that a burst can be continuously
output. A “data out of range” error will also be
generated.

Syntax

SOURce[1|2]:BURSt:INTernal:PERiod
{|MINimum|MAXimum}

Parameter

1 ms ~ 500 seconds

Example

SOUR1:BURS:INT:PER +1.0000E+01

Sets the period to 10 seconds.

Query Syntax

SOURce[1|2]:BURSt:INTernal:PERiod?
[MINimum|MAXimum]

Return Parameter

Returns the burst period in seconds.

Example

SOUR1:BURS:INT:PER?
+1.0000E+01

The burst period is 10 seconds.