Source[1|2]:frequency:start, Source[1|2]:frequency:stop – GW Instek AFG-2225 User Manual User Manual

Page 242

background image

AFG-2225 Series User Manual

242

SOURce[1|2]:FREQuency:STARt

Source Specific
Command

Description

Sets the start frequency of the sweep. 100Hz is the
default start frequency.

Note

To sweep up or down, set the stop frequency
higher or lower than the start frequency.

Syntax

SOURce[1|2]:FREQuency:STARt
{|MINimum|MAXimum}

Parameter

1μHz~ 25MHz
1μHz~ 15MHz(Square)
1μHz~ 1MHz (Ramp)

Example

SOUR1:FREQ:STAR +2.0000E+03

Sets the start frequency to 2kHz.

Query Syntax

SOURce[1|2]:FREQuency:STARt? [MINimum|
MAXimum]

Return Parameter

Returns the start frequency
in Hz.

Example

SOUR1:FREQ:STAR? MAX
+8.0000E+0

Returns the maximum start frequency allowed.

SOURce[1|2]:FREQuency:STOP

Source Specific
Command

Description

Sets the stop frequency of the sweep. 1 kHz is the
default start frequency.

Note

To sweep up or down, set the stop frequency
higher or lower than the start frequency.

Syntax

SOURce[1|2]:FREQuency:STOP
{|MINimum|MAXimum}