beautypg.com

Source[1|2]:frequency – GW Instek AFG-2225 User Manual User Manual

Page 207

background image

REMOTE INTERFACE

207

Sine

Square Ramp Pulse Noise ARB

AM

FM

PM

FSK

SUM

SWEEP   

BURST   

Syntax

SOURce[1|2]:FUNCtion {SINusoid|SQUare|RAMP|
PULSe|NOISe| USER}

Example

SOUR1:FUNC SIN

Sets the output as a sine function.

Query Syntax

SOURce[1|2]:FUNCtion?

Return Parameter SIN, SQU, RAMP, PULS,

NOIS, USER

Returns the current output
type.

Example

SOUR1:FUNC?

SIN

Current output is sine.

SOURce[1|2]:FREQuency

Source Specific
Command

Description

The SOURce[1|2]:FREQuency command sets the
output freuquency for the selected channel. The
query command returns the current frequency
setting.

Note

The maximum and minimum frequency depends
on the function mode.

Sine, Square

1μHz~25MHz

Ramp

1μHz~1MHz

Pulse