beautypg.com

Sweep time, Afg-2225 series user manual, Panel operation 1. press the sweep key – GW Instek AFG-2225 User Manual User Manual

Page 114: Press f5 (more), Press f1 (swp time), Press f1~f2 to select the time unit

background image

AFG-2225 Series User Manual

114

Sweep Time

The sweep time is used to determine how long it takes to perform a
sweep from the start to stop frequencies. The function generator
automatically determines the number of discrete frequencies used in
the scan depending on the length of the scan.

Panel Operation

1. Press the SWEEP key.



2. Press F5 (More).

or



3. Press F1 (SWP Time).

m



4. The Time parameter will become highlighted in

the waveform display area.

5. Use the selector keys and

scroll wheel or number pad
to enter the Sweep time.

/

6. Press F1~F2 to select the time

unit.

m



~



