7. Setting the Home
68
(3) Click the parameter button.
(4) Open the user parameter screen.
(5) Change the setting of User Parameter No. 22 (home return offset).
* The setting unit is mm.
Add or subtract the value measured in (2) to/from the value currently entered.
Example: If the difference is “-0.5 mm”:
Home return offset = Current setting – 0.5 mm
Click this button to open the parameter edit screen.
This manual is related to the following products:
- RCS3PCR-SA8C RCS3CR-SS8C RCS3CR-SA8C RCS3P-SS8C RCS3P-SA8C RCS3-SS8C RCS3-SA8C RCS2CR-SS8C RCS2CR-SS7C RCS2CR-SA7C RCS2CR-SA6D RCS2CR-SA6C RCS2CR-SA5D RCS2CR-SA5C RCS2CR-SA4C RCS2-SS8R RCS2-SS8C RCS2-SS7R RCS2-SS7C RCS2-SA7R RCS2-SA7C RCS2-SA6R RCS2-SA6D RCS2-SA6C RCS2-SA5R RCS2-SA5D RCS2-SA5C RCS2-SA4R RCS2-SA4D RCS2-SA4C