IAI America RCS3PCR-SS8C User Manual
Page 47

2. Specification
38
(5) Cleanliness class of clean room type RCP2CR
Item
Specification
Cleanliness
class
Class 10 (1 �m) when air is suctioned from the suction joint at an appropriate rate of
suction
(6) Common specifications
[RCS2, Cleanroom specification RCS2CR]
Item
Specification
Positioning repeatability
�
0.02 mm
Lost motion
0.1 mm or less
[RCS3(P), Cleanroom specification RCS3(P)CR]
Item
Specification
Positioning repeatability
�
0.02 mm [�0.01 mm]
Lost motion
0.1 mm or less [0.05 mm or less]
The values in [ ] apply to the high-precision type.
This manual is related to the following products:
- RCS3PCR-SA8C RCS3CR-SS8C RCS3CR-SA8C RCS3P-SS8C RCS3P-SA8C RCS3-SS8C RCS3-SA8C RCS2CR-SS8C RCS2CR-SS7C RCS2CR-SA7C RCS2CR-SA6D RCS2CR-SA6C RCS2CR-SA5D RCS2CR-SA5C RCS2CR-SA4C RCS2-SS8R RCS2-SS8C RCS2-SS7R RCS2-SS7C RCS2-SA7R RCS2-SA7C RCS2-SA6R RCS2-SA6D RCS2-SA6C RCS2-SA5R RCS2-SA5D RCS2-SA5C RCS2-SA4R RCS2-SA4D RCS2-SA4C