11. Maintenance and Inspection

191

6) Use an Allen wench of 2.5 mm across flats to remove the motor end cap bolts.

Use a screwdriver to remove the ground terminal bolt.

7) Pull out the motor-end cap.

8) Pull out the motor-end cover to expose the motor.

Caution: Caution: Never touch the encoder. Doing so may cause the encoder position to

shift, in which case the encoder will no longer operate properly.

Ground terminal bolt

Motor end cap bolts