6. Connection with Controllers
61
When fixing the cable, provide a moderate slack and do not tension it too tight.
Separate the I/O lines and communication lines from the power/drive lines. Do not bundle them together in
the duct.
Warning:
necting any cable, be sure to turn off the controller power first. If
a cable is connected or disconnected while the power is still supplied, the actuator may
malfunction and a serious injury or equipment damage may result.
firmly in place, because any loose connector may
cause the actuator to malfunction and create a dangerous situation.
Do not use a spiral tube where
the cable flexes frequently.
Power line
Signal lines (flat cable)
Duct
Follow the instructions below when using a cable track.
• If there is an indication to the cable for the space factor in a cable track, refer to the wiring instruction given
by the supplier when storing the cable in the cable track.
• Avoid the cables to get twined or twisted in the cable track, and also to have the cables move freely and do
not tie them up. (Avoid tension being applied when the cables are bent.)
Do not pile up cables. It may cause faster abrasion of the sheaths or cable breakage.
- RCS3PCR-SA8C RCS3CR-SS8C RCS3CR-SA8C RCS3P-SS8C RCS3P-SA8C RCS3-SS8C RCS3-SA8C RCS2CR-SS8C RCS2CR-SS7C RCS2CR-SA7C RCS2CR-SA6D RCS2CR-SA6C RCS2CR-SA5D RCS2CR-SA5C RCS2CR-SA4C RCS2-SS8R RCS2-SS8C RCS2-SS7R RCS2-SS7C RCS2-SA7R RCS2-SA7C RCS2-SA6R RCS2-SA6D RCS2-SA6C RCS2-SA5R RCS2-SA5D RCS2-SA5C RCS2-SA4R RCS2-SA4D RCS2-SA4C