4.Installation and Storage/Preservation Environment

43

�����

�����

�����

4. Installation and Storage/Preservation Environment

4.1 Installation Environment

The actuator should be set up in an environment, which meets the following criteria:

Avoid direct sunlight.

Avoid radiant heat from strong heat sources such as a furnace.

Surrounding air temperature should be 0 ~ 40�C.

The humidity should be less than 85% and there should be no condensation.

Avoid exposure to corrosive or combustible gases.

The area should have very little dust and be suitable for normal assembly operations.

Avoid exposure to oil mist or fluids used in cutting.

The unit should not be subject to impacts or vibrations.

Avoid extreme electromagnetic waves, ultraviolet rays and radiation.

This product is not intended to be used in a chemical environment.

In general, the environment should be one in which an operator can work without protective gear.

Work space needed for maintenance/inspection

[Motor straight type]

[Motor reversing type]

4.2 Storage/Preservation Environment

The storage/preservation environment should be similar to the installation environment. In addition, you must

take precautions against condensation if the unit is to be stored for a long period of time. Unless there are

special instructions, we do not include moisture absorption agents when shipping the unit. If you are storing the

unit where condensation might occur, then you must treat the entire package or treat the unit itself after it is

unpacked to prevent condensation. The unit can withstand up to 60�C during a short storage/preservation

interval but only up to 50�C if the storage/preservation period is longer than one month.