beautypg.com

1 important information, 1 required equipment, 2 upgrade steps – Clear-Com Eclipse-Omega User Manual

Page 95: Ics-2003 series panels, Eclipse upgrade reference manual

background image

Eclipse Upgrade Reference Manual

Clear-Com Communication Systems

Page 95 of 155

Part Number: 810377Z Rev 6

11.2 ICS-2003 Series Panels

11.2.1 Important Information

Before attempting any upgrade, ensure that anti static precautions are taken, as the
Eclipse items are sensitive to static discharges.


11.2.1.1 Required

Equipment

1. 2 off 1 MBit PROM device – ATMEL AT29C010A or equivalent
2. PROM Programming unit
3. PROM programming software appropriate for the unit
4. Appropriate EVEN ‘S’ record file for ICS2003 panel
5. Appropriate ODD ‘S’ record file for ICS2003 panel


11.2.1.2 Upgrade

Steps

1. Ensure that the PROM device to be programmed is empty
2. Program the PROM device with the appropriate EVEN file according to the

instructions for the PROM programmer being used.

3. Confirm that the checksum of the programmed device matches that detailed in

the Eclipse release notes.

4. Repeat steps 1 through 3 for the ODD PROM file image
5. Remove the existing PROM devices from the ICS2003 panel.
6. Insert the newly programmed PROM devices taking care to ensure the correct

polarity of the devices.


For Analogue CAT5 connections direct to the Matrix use the Analogue software:

• InstallCD\Panel Software\ICS-2003\Analog\710648Z - Odd

PROM\710648Z.BIN

• InstallCD\Panel Software\ICS-2003\Analog\710649Z - Even

PROM\710649Z.BIN


For DIGITAL connections via a DIGI2 interface to the Matrix use the Digital software:

• InstallCD\Panel Software\ICS-2003\Digital\710650Z - Odd

PROM\710650Z.BIN

This manual is related to the following products: