13. A temporary IP address will be required for the E-QUE card if it is connected to
the network, that will be used just during the upgrade process. This address
needs to be on the same subnet as the PC performing the upgrade (i.e. if the
IP address of the PC is 192.168.1.1, then the IP address of the E-Que card
has to be 192.168.1.. If the network cable
from the config card is used to connect the E-QUE then the config card IP
address could be re-used. If the E-QUE card is connected by an ethernet
crossover any IP address which is on the same subnet as the PC can be used.
Note: The ip address of the PC can be determined by opening up a DOS
prompt window and typing "ipconfig". The IP address will be displayed in
the DOS window.
14. Run the macro, eque_upgrade.ttl, from TeraTerm by selecting "Control-
>Macro" then browsing to the directory it was copied to (see step 6).
Figure 75 - TeraTerm Control Options
15. This will open a small window (which may open minimized or behind another
window) titled "MACRO - eque_upgrade.ttl".