5 pd4224e panel, Required equipment, 2 upgrade steps – Clear-Com Eclipse-Omega User Manual
Page 101: Pd4294e panel, Eclipse upgrade reference manual
Eclipse Upgrade Reference Manual
Clear-Com Communication Systems
Page 101 of 155
Part Number: 810377Z Rev 6
11.3.5 PD4224E Panel
11.3.5.1 Required
Equipment
1. 512 KBit PROM device – ST M27C512 or equivalent.
2. PROM Programming unit.
3. PROM programming software appropriate for the unit.
4. Appropriate ‘S’ record file for 4224 panel.
11.3.5.2 Upgrade
Steps
1. Ensure that the PROM device to be programmed is empty.
2. Program the PROM device with the appropriate file according to the
instructions for the PROM programmer being used.
3. Confirm that the checksum of the programmed device matches that detailed in
the Eclipse release notes.
4. Remove the existing PROM device from the 4224 panel.
5. Insert the newly programmed PROM device taking care to ensure the correct
polarity of the device.
For PD4224E panels purchased Before 1-July-2006
InstallCD\Panel_Software\ 4000 - 4224 +\ 710705Z - 4224E-4226E-4294E-
4215E Panel Boot Code\710705Z-PROG-01.S
For PD4224E panels purchased After 1-July-2006
InstallCD\Panel_Software\ 4000 - 4224 +\ 710800Z - 4224E-4226E-4294E-
4215E Panel Boot Code (Unleaded)\710800Z-PROG-01.S